SKU: E708-690 · In stock
This spO2 adapter cable is available for use with Covidien > Nellcor: N-3000, N-390, N-395, N-6000, NPB-290, NPB-295, Symphony N-3000; Datex Ohmeda: AS/3, CS/3, Cardiocap/5, S/5, enGuard CM5; GE Healthcare > Critikon > Dinamap: M-NSAT Modules, Pro 1000, Pro 300, Pro 400, Pro Series, ProCare; Invivo: MDE Escort Prism; Mindray > Datascope: Accutorr Plus, Accutorr Plus (Nellcor), Duo, Passport 2, Passport XG, Spectrum, Trio; Mortara: Surveyor S12/S19; Nihon Kohden: BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100; Omron > Colin: BP-306, BP-508, BP-808, BP-88, BP-88S, Press-Mate; Oridion: Capnostream 20; Philips: Prodigy, VS1; Stryker > Medtronic > Physio Control: Lifepak 12; Welch Allyn: 1500, 42NT0-E1 LXi, Spot Vital Signs 42NTB-E1; Zoll: E Series, M Series, R Series.
Compatibility
| Manufacturer | Models |
|---|---|
| Covidien > Nellcor | N-3000, N-390, N-395, N-6000, NPB-290, NPB-295, Symphony N-3000 |
| Datex Ohmeda | AS/3, CS/3, Cardiocap/5, S/5, enGuard CM5 |
| GE Healthcare > Critikon > Dinamap | M-NSAT Modules, Pro 1000, Pro 300, Pro 400, Pro Series, ProCare |
| Invivo | MDE Escort Prism |
| Mindray > Datascope | Accutorr Plus, Accutorr Plus (Nellcor), Duo, Passport 2, Passport XG, Spectrum, Trio |
| Mortara | Surveyor S12/S19 |
| Nihon Kohden | BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100 |
| Omron > Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, Press-Mate |
| Oridion | Capnostream 20 |
| Philips | Prodigy, VS1 |
| Stryker > Medtronic > Physio Control | Lifepak 12 |
| Welch Allyn | 1500, 42NT0-E1 LXi, Spot Vital Signs 42NTB-E1 |
| Zoll | E Series, M Series, R Series |
OEM Part Number Cross References
| Manufacturer | Part Number |
|---|---|
| AMC | CB-A400-1011SC |
| Beta Biomed | B505-1011A |
| Covidien > Nellcor | SCP-10, MC-10 |
| Datex Ohmeda | 903131 |
| Envitec | X-4213 |
| Mindray > Datascope | 0012-00-1254 |
| Nihon Kohden | NK-SCP-10 |
| Pacific Medical | NXNE300 |
| Sage | E06-30M |
| Tenacore | TE1723 |
| Welch Allyn | 9293-057-51 |
Technical Specifications
| Sold By | Cables and Sensors |
| Compatible Manufacturers | AMC, Beta Biomed, Covidien > Nellcor, Datex Ohmeda, Envitec, GE Healthcare > Critikon > Dinamap, Invivo, Medtronic > Physio Control, Mindray > Datascope, Mortara, Nihon Kohden, Omron > Colin, Oridion, Pacific Medical, Philips, Sage, Stryker > Medtronic > Physio Control, Tenacore, Welch Allyn |
| Latex-free | Yes |
| Discount | Reusable |
| Sterile | No |
| Cable Color | Gray |
| Cable Diameter | 4 mm |
| Category | SpO2 |
| Certifications | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant |
| Connector Distal | DB 14-pin connector |
| Connector Proximal | Female 9-Pin D-Sub Connector |
| Packaging Type | Bag |
| Packaging Unit | 1 |
| SpO2 Technology | Nellcor OxiSmart |
| Total Cable Length | 7 ft |
| Warranty | 12 months |
| Weight | 0.3lb |